ETI SV 140 1-pole 40A disconnect switch for load isolation

ETI SV 140 1-pole 40A disconnect switch for load isolation
ETI SV 140 1-pole 40A disconnect switch for load isolation
Characteristics

Категорія

Вимикач навантаження

Призначення

Вимикач навантаження

Номінальний струм (A)

40A

ETI

Code: 2423123

ETI SV 140 1-pole 40A disconnect switch for load isolation

SV 140 is a load break switch for switching electrical circuits under load. The ETI model has 1 pole and a rated current of 40A, making it suitable for circuit isolation and control in electrical installations.

per pcs.

195.69 ₴

On Order

Quick order
Delivery

Delivery across Ukraine within 5 days from the purchase date.

Payment

Pay for orders via Liqpay and plata by mono services.

Guarantee

100% certified products. Service and support.

About product

The ETI SV 140 load break switch is designed for switching electrical circuits under load in distribution boards and other electrical installations. It is used where a circuit must be manually connected or disconnected without interrupting the overall logic of the electrical system, providing clear local control of power supply to a single circuit. Such devices are commonly applied in residential, commercial, and industrial installations where routine isolation of equipment or individual lines is required.

This model has 1 pole, so it is intended for control of a single phase line. The rated current is 40 A, which makes the device suitable for circuits with corresponding load levels. With this rating, the load break switch can be integrated into supply schemes for separate consumer groups and into assemblies where manual disconnection under operating current is needed. Its single-pole configuration also simplifies use in compact modular arrangements, especially in distribution panels where space and functional clarity are important.

Unlike protective switching devices, a load break switch is focused on operational switching rather than automatic disconnection during fault conditions. Its main role is to provide controlled opening and closing of the circuit under load, which is particularly important during maintenance of panel equipment, redistribution of loads, or local isolation of a specific line. This makes the SV 140 a practical component in electrical systems that require manual control of power flow.

The ETI SV 140 fits standard electrical installation scenarios where a straightforward switching device with a 40 A rating is needed. It is suitable for use as part of a structured distribution system, helping organize safe and convenient circuit isolation within the electrical network. The combination of 1-pole design and rated current of 40 A defines its application in single-line control tasks, where reliable manual switching is the primary requirement.

Головна

Категорія

Вимикач навантаження

Призначення

Вимикач навантаження

Номінальний струм (A)

40A

-

0 reviews

No reviews for this product yet. Be the first!

Recently Viewed

Room thermostat Schneider Electric 8A with built-in sensor, anthracite (NU350154)
Room thermostat Schneider Electric 8A with built-in sensor, anthracite (NU350154)

Термостат кімнатний, вбудованний датчик 8А антрацит

ETI SV 216 disconnect switch 2-pole 16A
ETI SV 216 disconnect switch 2-pole 16A

ETI SV 216 is a load break switch intended for manual switching of electrical circuits under load in low-voltage distribution systems. It is used for...

Legrand NILOE STEP decorative mounting frame, 1 post, aluminium
Legrand NILOE STEP decorative mounting frame, 1 post, aluminium

Legrand NILOE STEP 1-post frame for sockets or switches. Thermoplastic body, aluminium colour, concealed mounting, IP20, IK04.

Hager CDA440D RCD 4-pole 40 A 30 mA Type A DIN rail 4 modules
Hager CDA440D RCD 4-pole 40 A 30 mA Type A DIN rail 4 modules

4-pole Hager residual current device for 400 V AC systems, rated at 40 A with 30 mA residual operating current, Type A, DIN-rail mounting, IP20, 4 mod...

Hager SBN332 disconnect switch, 3-pole, 32 A, 400 V, IP20
Hager SBN332 disconnect switch, 3-pole, 32 A, 400 V, IP20

Manual load breaker for AC circuits, 3 poles, 32 A, 400 V, IP20, 2 modules, 3 normally open contacts.

Room thermostat Schneider Electric 8A with built-in sensor, aluminium (NU350130)
Room thermostat Schneider Electric 8A with built-in sensor, aluminium (NU350130)

Термостат кімнатний, вбудованний датчик 8А алюміній

Hager CDA240D RCD, 2-pole, 40 A, 30 mA, Type A, DIN-rail mounted
Hager CDA240D RCD, 2-pole, 40 A, 30 mA, Type A, DIN-rail mounted

Two-pole Hager residual current device for 230 V AC networks, rated 40 A, 30 mA, Type A, DIN-rail mounting.

Load break switch Hager SBN340, 3-pole, 40 A/400 V
Load break switch Hager SBN340, 3-pole, 40 A/400 V

Three-pole load break switch for 400 V AC circuits, rated at 40 A, with IP20 protection, modular width of 3 pitches, and 68 mm installation depth.

Load Break Switch Hager SBN363 3-Pole 63 A 400 V IP20
Load Break Switch Hager SBN363 3-Pole 63 A 400 V IP20

Three-pole load break switch for manual switching of AC circuits in distribution boards. Rated for 63 A, 400 V, with IP20 protection, 3 module widths,...

End caps for busbars Schneider Electric 1P, 10 pcs (A9XPE110)
End caps for busbars Schneider Electric 1P, 10 pcs (A9XPE110)

10 КІНЦЕВИХ.КОВПАЧКІВ ДЛЯ ГР.ШИНОК 1П