ETIMAT 10 by ETI 2-pole 63A D-curve circuit breaker 6kA

ETIMAT 10 by ETI 2-pole 63A D-curve circuit breaker 6kA
ETIMAT 10 by ETI 2-pole 63A D-curve circuit breaker 6kA
Characteristics

Категорія

Автоматичний вимикач

Номінальний струм (A)

63A

Характеристика спрацювання

D

Кількість полюсів

2

Вимикаюча здатність (кА)

6kA

Тип напруги

AC

Номінальна імпульсна напруга Uimp (kV)

6kV

Номінальна напруга AC (В)

400V

ETI

Code: 2153722

ETIMAT 10 by ETI 2-pole 63A D-curve circuit breaker 6kA

The ETIMAT 10 circuit breaker is designed to protect electrical circuits from overload and short circuit. It has 2 poles, a rated current of 63A, D tripping characteristic, and a breaking capacity of 6kA.

per pcs.

1,506.09 ₴

On Order

Quick order
Delivery

Delivery across Ukraine within 5 days from the purchase date.

Payment

Pay for orders via Liqpay and plata by mono services.

Guarantee

100% certified products. Service and support.

About product

The ETI ETIMAT 10 circuit breaker is designed for protecting electrical circuits against overloads and short circuits in distribution boards used in residential, commercial, and industrial installations. It is intended for line protection where automatic disconnection is required under fault conditions, helping to maintain the safety and stability of the electrical network.

This device has 2 poles, so it can disconnect two conductors simultaneously. Such configuration is suitable for single-phase circuits with two-pole disconnection or for other circuit designs where both lines must be interrupted together. The rated current is 63 A, which makes the breaker appropriate for circuits with corresponding load requirements. The D tripping characteristic is used in circuits with high inrush currents, such as those with electric motors, transformers, or other equipment that produces short-term start-up surges. This characteristic allows the breaker to tolerate temporary current peaks without unnecessary tripping.

The breaking capacity of 6 kA defines the device’s ability to safely interrupt short-circuit currents up to the declared value. This is an important selection parameter for low-voltage installations, as it must match the expected fault current level in the network. The breaker operates on AC systems with a rated voltage of 400 V and a rated frequency of 50/60 Hz. In addition, the rated impulse withstand voltage Uimp of 6 kV indicates resistance to transient overvoltages that may occur in electrical systems.

For wiring connection, the nominal conductor cross-section range is 1–25 mm², which should be taken into account during installation and cable sizing. The device complies with IEC/EN 60898-1 and IEC 60947-2 standards, confirming its conformity to the requirements for miniature circuit breakers and protective switching devices. With its 2-pole design, 63 A current rating, D curve, and 6 kA breaking capacity, the ETIMAT 10 provides circuit protection in installations where both load current and starting currents must be considered.

Головна

Категорія

Автоматичний вимикач

Номінальний струм (A)

63A

Характеристика спрацювання

D

Кількість полюсів

2

Вимикаюча здатність (кА)

6kA

Тип напруги

AC

Номінальна імпульсна напруга Uimp (kV)

6kV

Номінальна напруга AC (В)

400V

Номінальна частота (Hz)

50Hz/60Hz

Номінальний перетин

1mm²-25mm²

Стандарт

IEC/EN 60898-1,IEC 60947-2

Призначення

Автоматичний вимикач

-