Catalog HOUSEHOLD AND COMMERCIAL EQUIPMENT Modular protective and switching equipment Circuit breakers ETIMAT 10 molded-case circuit breaker 1P 80A curve D 20kA ETI

ETIMAT 10 molded-case circuit breaker 1P 80A curve D 20kA ETI

ETIMAT 10 molded-case circuit breaker 1P 80A curve D 20kA ETI
ETIMAT 10 molded-case circuit breaker 1P 80A curve D 20kA ETI
Characteristics

Категорія

Автоматичний вимикач

Номінальний струм (A)

80A

Характеристика спрацювання

D

Кількість полюсів

1

Вимикаюча здатність (кА)

20kA

Тип напруги

AC

Номінальна імпульсна напруга Uimp (kV)

4kV

Номінальна напруга AC (В)

240V/415V

ETI

Code: 2151731

ETIMAT 10 molded-case circuit breaker 1P 80A curve D 20kA ETI

ETIMAT 10 is an automatic circuit breaker for protecting electrical circuits against overloads and short circuits. It has 1 pole, rated current 80A, tripping characteristic D, and breaking capacity 20kA.

per pcs.

1,830.57 ₴

On Order

Quick order
Delivery

Delivery across Ukraine within 5 days from the purchase date.

Payment

Pay for orders via Liqpay and plata by mono services.

Guarantee

100% certified products. Service and support.

About product

ETIMAT 10 by ETI is an automatic circuit breaker designed to protect electrical circuits against overloads and short circuits in AC networks. With a single pole, it is intended for use in single-phase lines where separate disconnection of one conductor is required. The rated current of 80 A makes this device suitable for circuits with elevated load, while the D tripping characteristic indicates use in circuits with high inrush currents, including applications with electric motors or other equipment that creates brief startup surges.The breaking capacity of 20 kA is an important parameter for distribution boards and power circuits, as it allows the device to interrupt high short-circuit currents. The breaker is designed for AC operation with a rated voltage of 240/415 V and a rated frequency of 50/60 Hz, which makes it applicable in different alternating-current power systems. The rated impulse withstand voltage Uimp is 4 kV, confirming its ability to withstand temporary voltage surges within the specified operating conditions.For conductor connection, the device supports a rated cross-section of 25–50 mm², which should be taken into account during system design and installation. This makes it suitable for circuits where larger conductor sizes are required to match the load and installation conditions. The product complies with IEC/EN 60898-1 and IEC 60947-2 standards, which define requirements for low-voltage circuit breakers and confirm its suitability for use in corresponding electrical installations.As a 1P, 80 A breaker with D curve tripping and 20 kA breaking capacity, this model is used in power distribution systems where reliable line protection and tolerance to high starting currents are needed. It is a practical choice for switchboards in residential, commercial, and technical electrical installations, especially where the circuit may be exposed to demanding load conditions.

Головна

Категорія

Автоматичний вимикач

Номінальний струм (A)

80A

Характеристика спрацювання

D

Кількість полюсів

1

Вимикаюча здатність (кА)

20kA

Тип напруги

AC

Номінальна імпульсна напруга Uimp (kV)

4kV

Номінальна напруга AC (В)

240V/415V

Номінальна частота (Hz)

50Hz/60Hz

Номінальний перетин

25mm²-50mm²

Стандарт

IEC/EN 60898-1,IEC 60947-2

Призначення

Автоматичний вимикач

-

0 reviews

No reviews for this product yet. Be the first!