Characteristics

Категорія

ETIMAT P10 2p D50

Номінальний струм (A)

50A

Характеристика спрацювання

D

Кількість полюсів

2

Вимикаюча здатність (кА)

10kA

Тип напруги

AC

Номінальна імпульсна напруга Uimp (kV)

6kV

Номінальна напруга AC (В)

400V

ETI

Code: 1901255_ETI

ETI ETIMAT P10 50A 2-pole D curve circuit breaker 10kA

Circuit breaker from the ETIMAT P10 series is designed to protect electrical circuits against overloads and short circuits. It has 2 poles, a rated current of 50A, D tripping characteristic, and breaking capacity of 10kA.

per pcs.

1,248.00 ₴

In Stock

Quick order
Delivery

Delivery across Ukraine within 5 days from the purchase date.

Payment

Pay for orders via Liqpay and plata by mono services.

Guarantee

100% certified products. Service and support.

About product

The ETIMAT P10 series circuit breaker by ETI is designed to protect low-voltage electrical circuits against overloads and short circuits in residential, commercial, and small industrial distribution systems. Its 2-pole design allows simultaneous switching of two conductors, which is appropriate for circuits where both poles need to be disconnected together. This device is rated for a current of 50 A, making it suitable for circuits with higher load levels. The D tripping characteristic indicates use in circuits with pronounced inrush currents, such as equipment that briefly draws a current higher than its normal operating value during startup. For this reason, the breaker can be used where standard tripping curves would be too sensitive to transient current peaks. The breaking capacity of 10 kA means the device is intended to interrupt high short-circuit currents within the limits of the electrical network for which it is selected. It operates on AC systems with a rated voltage of 400 V and a frequency of 50/60 Hz, which corresponds to common supply conditions in low-voltage installations. The rated impulse withstand voltage Uimp is 6 kV, indicating resistance to short-term overvoltages that may occur in the network. Installation and conductor selection should also take into account the rated conductor cross-section of 125 mm². This parameter is important during panel design and wiring, as it helps ensure proper connection of the breaker within the distribution board. The product complies with EN/IEC 60898, the standard governing key requirements for circuit breakers used in the protection of low-voltage circuits. ETIMAT P10 is a modular protective device intended for installation in an electrical panel. It combines 2-pole switching, D curve behavior, 50 A rated current, and 10 kA breaking capacity, making it suitable for circuits where both higher load handling and reliable response to inrush currents are required.
Головна

Категорія

ETIMAT P10 2p D50

Номінальний струм (A)

50A

Характеристика спрацювання

D

Кількість полюсів

2

Вимикаюча здатність (кА)

10kA

Тип напруги

AC

Номінальна імпульсна напруга Uimp (kV)

6kV

Номінальна напруга AC (В)

400V

Номінальна частота (Hz)

50Hz/60Hz

Номінальний перетин

125mm²

Стандарт

EN/IEC 60898